It is equipped with low pressure UV-lamps, powered by electronic high frequency ballasts, for highest efficiency and lowest power consumption.
The sterilization process is microprocessor-controlled via data from the UV-sensor. The intelligent lamp monitoring system will, in case of any lamp failure, inform the user of this occurrence as well as the location of the broken lamp.
The hour meter tells the user to change lamps when the limit of its using time is reached.
All necessary data is available in a display window on the control cabinet.
Maximum flow at different water qualities (m³/h). Normally the Max/Min capacity of a UV-unit is chosen between T50=90% down to T50=60%.
| T10=100% | T10=98% | T10=96% | T10=93% | T10=90% | T10=87% | T10=83% | |
| Size | T50=100% | T50=80% | T50=80% | T50=70% | T50=60% | T50=50% | T50=40% |
| UV1 | 1.41 | 1.28 | 1.15 | 1.01 | 0.88 | 0.74 | 0.60 |
| UV2 | 1.98 | 1.79 | 1.61 | 1.42 | 1.24 | 1.04 | 0.85 |
| UV3 | 4.59 | 4.05 | 3.51 | 3.01 | 2.53 | 2.06 | 1.62 |
| UV4 | 6.98 | 6.13 | 5.30 | 4.54 | 3.82 | 3.13 | 2.49 |
| UV5 | 12.49 | 10.52 | 8.73 | 7.17 | 5.79 | 4.55 | 3.45 |
| UV31 | 15.88 | 14.00 | 12.14 | 10.41 | 8.75 | 7.13 | 5.60 |
| UV41 | 24.09 | 21.13 | 18.28 | 15.67 | 13.21 | 10.86 | 8.66 |
| UV51 | 43.20 | 36.39 | 30.19 | 24.82 | 20.03 | 15.73 | 11.94 |
| Voltage: | 110/230 VAC 50/60 Hz |
| Power consumption: | 35-290W depending on size |
| UV-dosage: | 36000 Ws/cm² |
| Alarm: | Open/closed 1A resistive Relay output, normally |
| Working pressure: | Max 10 bar |
| Material chamber: | Stainless Steel 316L |
| Weight: | 15-25 kg (up to sizes) |
Click on link to download
Click below to enlarge picture
JOWA AB Tulebovägen 104, S-428 34 Kållered, Sweden Tel: +46-31 726 54 00, Fax: +46-31 795 45 40, E-mail: info@jowa.se